1.5Kg/h 家用除湿机翅片式换热器设计案例




选择1690W的卧式压缩机,参数如下:https://pic3.zhimg.com/80/v2-1fa38640ac4a3bc32b735c06ae5df54e_720w.jpg一、制冷系统初步热力计算:利用Excel进行热力计算,得到如下结果:https://pic3.zhimg.com/80/v2-e512d0f3e70262f209e83da4cf37f73e_720w.jpghttps://pic1.zhimg.com/80/v2-0b1f745317e680a9d0cc0cd115e675b4_720w.jpg二、蒸发器设计:蒸发器的试算:https://pic3.zhimg.com/80/v2-9d7752322344b53f16205ca2271620c6_720w.jpg我们将初步的设计参数,输入到Coildesigner软件中,进行复核计算,得到如下的参数结果:https://pic1.zhimg.com/80/v2-ce100c9083b684367da2bfa83c238988_720w.jpghttps://pic4.zhimg.com/80/v2-47c328dbc2fc72cca82cad981bf9e7af_720w.jpghttps://pic3.zhimg.com/80/v2-cf86e0e443be06ebb1c365d1a1ef6fc2_720w.jpg满足设计需求。三、冷凝器设计:冷凝器的试算:https://pic3.zhimg.com/80/v2-739957650ce86b743dfca6b70be7e696_720w.jpg我们将初步的设计参数,输入到Coildesigner软件中,进行复核计算,得到如下的参数结果:https://pic2.zhimg.com/80/v2-81407b453ee4825195724b37f55ea5d1_720w.jpghttps://pic1.zhimg.com/80/v2-30f4294f55ce6be1569d0d2ed9e78030_720w.jpghttps://pic3.zhimg.com/80/v2-7e437486bd313e3e61cbf5eaaa9ff46e_720w.jpghttps://pic1.zhimg.com/80/v2-855496d4d6ede64399d555a9bf146634_720w.jpg满足设计需求。